American Dryer Corp. AD-200 Tilting Manuel de l'opérateur

Naviguer en ligne ou télécharger Manuel de l'opérateur pour Sèche-linge électrique American Dryer Corp. AD-200 Tilting. American Dryer Corp. AD-200 Tilting Operator`s manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 70
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
For replacement parts, contact the distributor from which the dryer
was purchased or
American Dryer Corporation
88 Currant Road
Fall River MA 02720-4781
Telephone: (508) 678-9000 / Fax: (508) 678-9447
123099DMG/tcosta ADC Part No. 113109
WARNING: For your safety the
information in this manual must be
followed to minimize the risk of fire or
explosion or to prevent property damage,
personal injury or death.
Do not store or use gasoline or other flammable
vapor and liquids in the vicinity of this or any
other appliance.
WHAT DO YOU DO IF YOU SMELL GAS
* Do not try to light any appliance.
* Do not touch any electrical switch; do not use
any phone in your building.
* Clear the room, building or area of all
occupants.
* Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
* If you cannot reach your gas supplier, call the
fire department.
Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
AVERTISSEMENT: Assurez-vous de bien
suivre les instructions données dans cette
notice pour réduire au minimum le risque
d’incendie ou d’explosion ou pour éviter tout
dommage matériel, toute blessure ou la mort.
Ne pas entreposer ni utiliser d’essence ni
d’autres vapeurs ou liquides inflammables dans
le voisinage de cet appareil ou de tout autre
appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR
DE GAZ:
* Ne pas tenter d’allumer d’appareil.
* Ne touchez à aucun interrupteur. Ne pas
vous servir des téléphones se trouvant dans
le bâtiment où vous vous trouvez..
* Évacuez la pièce, le bâtiment ou la zone.
* Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions
du fournisseur.
* Si vous ne pouvez rejoindre le fournisseur
de gaz, appelez le service des incendies.
L’installation et l’entretien doivent être assurés
par un installateur ou un service d’entretien
qualifié ou par le fournisseur de gaz.
AD-200 Phase 7
(with Tilting Options)
Installation/Operator’s Manual
Vue de la page 0
1 2 3 4 5 6 ... 69 70

Résumé du contenu

Page 1 - AD-200 Phase 7

For replacement parts, contact the distributor from which the dryerwas purchased orAmerican Dryer Corporation88 Currant RoadFall River MA 02720-4781Te

Page 2 - Important

6MAXIMUM CAPACITY (Dry Weight) 200 lbs. 90.9 kgTUMBLER (Basket) DIAMETER 62-1/2" 158.75 cmTUMBLER (Basket) DEPTH 42" 106.7 cmTUMBLER (Basket

Page 3 - FOR YOUR SAFETY

7B. DIMENSIONS and LOCATIONNOTE: ADC reserves the right to make changes in specifications at any time, without notice orobligation.

Page 4

8NOTE: ADC reserves the right to make changes in specifications at any time, without notice orobligation.

Page 5 - Table of Contents

9NOTE: ADC reserves the right to make changes in specifications at any time, without notice orobligation.

Page 6

10SECTION IIIINSTALLATION PROCEDURESInstallation in a proper location should be performed by competent technicians in accordance with local andstate c

Page 7 - SECTION I

11NOTE: ADC reserves the right to make changes in specifications at any time, without notice orobligation.1. Reassembly Instructions For Gas Dryer S

Page 8 - B. SAFETY PRECAUTIONS

12ADG-200 1 Door/2-Way Tilt

Page 9

13a. Reassembly For 1 Door/2-Way Tilt Gas Dryers;Lift the tumbler (basket) section onto the base.1) 2-Way Tilt dryers have four (4) tilting pistons in

Page 10 - GasSteam

142. Reassembly Instructions For Gas Dryer Shipped In Two PiecesADG-200 1 Door/Forward TiltNOTE: ADC reserves the right to make changes in specificat

Page 11 - B. DIMENSIONS and LOCATION

15ADG-200 1 Door/Forward Tilt

Page 12

Retain This Manual In A Safe Place For Future ReferenceAmerican Dryer Corporation products embody advanced concepts in engineering, design, and safety

Page 13

16a. Reassembly For 1 Door/Forward Tilt Gas Dryers;Lift the tumbler (basket) section onto the base.1) Forward Tilt dryers have two (2) tilting pistons

Page 14 - SECTION III

173. Reassembly Instructions For Gas Dryer Shipped In Two PiecesADG-200 2 Door/Rear Tilt(Pass Thru)NOTE: ADC reserves the right to make changes in s

Page 15 - ADG-200 1 Door/2-Way Tilt

18ADG-200 2 Door/Rear Tilt(Pass Thru)

Page 16

19a. Reassembly For 2 Door/Rear Tilt (Pass Thru) Gas Dryers;Lift the tumbler (basket) section onto the base.1) Rear Tilt dryers have two (2) tilting p

Page 17

20NOTE: ADC reserves the right to make changes in specifications at any time, without notice orobligation.4. Reassembly Instructions For Steam Dryer

Page 18 - ADG-200 1 Door/Forward Tilt

21ADS-200 1 Door/2-Way Tilt

Page 19

22a. Reassembly For 1 Door/2-Way Tilt Steam Dryers;Lift the tumbler (basket) section onto the base.1) 2-Way Tilt dryers have four (4) tilting pistons

Page 20

235. Reassembly Instructions For Steam Dryer Shipped In Two PiecesADS-200 1 Door/Forward TiltNOTE: ADC reserves the right to make changes in specifi

Page 21 - ADG-200 2 Door/Rear Tilt

24ADS-200 1 Door/Forward Tilt

Page 22

25a. Reassembly For 1 Door/Forward Tilt Steam Dryers;Lift the tumbler (basket) section onto the base.1) Forward Tilt dryers have two (2) tilting pisto

Page 23

IMPORTANTYOU MUST DISCONNECT and LOCKOUT THE ELECTRIC SUPPLY and THE GASSUPPLY or THE STEAM SUPPLY BEFORE ANY COVERS or GUARDS AREREMOVED FROM THE MAC

Page 24 - ADS-200 1 Door/2-Way Tilt

26NOTE: ADC reserves the right to make changes in specifications at any time, without notice orobligation.6. Reassembly Instructions For Steam Dryer

Page 25

27ADS-200 2 Door/Rear Tilt(Pass Thru)

Page 26

28a. Reassembly For 1 Door/Forward Tilt Steam Dryers;Lift the tumbler (basket) section onto the base.1) Rear Tilt dryers have two (2) tilting pistons

Page 27 - ADS-200 1 Door/Forward Tilt

29B. LOCATION REQUIREMENTSThe model AD-200 tilting dryer requires 18-inches (45.72 cm) on the right side of the dryer for ease ofmaintenance. For th

Page 28

30C. FRESH AIR SUPPLY REQUIREMENTSWhen the dryer is operating, it draws in room air, heats it, passes this air through the tumbler (basket), andexhau

Page 29

31D. EXHAUST REQUIREMENTSNOTE: For 1 Door ADG-200 dryer models, the 20-inch (50.8 cm) diameter exhaust duct exitsfrom the rear of the base. For 2 Do

Page 30 - ADS-200 2 Door/Rear Tilt

32ALL duct work should be smooth inside with no projections from sheet metal screws or other obstructionswhich will collect lint. When adding ducts,

Page 31

332. Single Dryer VentingWhere possible, it is suggested to provide a separate exhaust duct for each dryer. The exhaust duct shouldbe laid out in suc

Page 32

34IMPORTANT: For extended duct work runs, the cross section area of the duct work can only beincreased to an extent. Maximum proportional duct work r

Page 33

35The main duct may be any shape so long as the minimum cross section area is provided. The illustration onpage 36 shows the minimum cross section ar

Page 34

WARNINGThe dryer must never be operated with any of the back guards, outer tops, or servicepanels removed. PERSONAL INJURY or FIRE COULD RESULT.IMPOR

Page 36

37E. COMPRESSED AIR SUPPLY SYSTEMThe compressed air system of the AD-200 Tilting dryer consists of a number of pneumatic pistons locatedthroughout th

Page 37

383. Internal/External Pilot Air SupplyOn 2-Way-Tilt dryers, a pneumatic safety circuit is incorporated to prevent both front and rear tilting pistons

Page 38

39F. ELECTRICAL INFORMATION1. Electrical RequirementsIt is your responsibility to have ALL electrical connections made by a properly licensed and com

Page 39

402. Electrical Service SpecificationsIMPORTANT: The dryer must be connected to the electric supply shown on the data label thatis affixed to the back

Page 40

41ADS-200 with Tilting Options15 HP Blower / 3 HP Drive MotorIMPORTANT: 208 VAC AND 230 VAC ARE NOT THE SAME. When ordering, specify exact voltage.

Page 41

423. Electrical ConnectionsNOTE: A wiring diagram is included with each dryer and is located in the blueprint pocketinside the left side control cabin

Page 42

43G. GAS INFORMATIONIt is your responsibility to have ALL plumbing connections made by a qualified professional to assure that thegas plumbing instal

Page 43 - F. ELECTRICAL INFORMATION

442. Technical Gas Dataa. Gas Specificationsb. Gas Connections:Run a 1-1/2” (3.81 cm) pipe from the main gas header to the dryer. There is a 1-1/2” (

Page 44 - ADG-200 with Tilting Options

453. Piping/ConnectionsALL components/materials must conform to National Fuel Gas Code specifications. It is important thatgas pressure regulators me

Page 45 - ADS-200 with Tilting Options

Table of ContentsSECTION IIMPORTANT INFORMATION ...

Page 46

46Consistent gas pressure is essential at ALL gas connections. It is recommended that a 2-inch (5.08 cm) pipegas loop be installed in the supply line

Page 47 - G. GAS INFORMATION

47H. STEAM INFORMATIONIt is your responsibility to have ALL plumbing connections made by a qualified professional to assure that thegas plumbing ins

Page 48 - Type of Gas

48d. Shut-off valves for each dryer should be installed in the supply line, return line, and drip trap returnlines. This will allow the dryer to be i

Page 49

493. Steam Damper Air System ConnectionsThe ADS-200 is manufactured with a pneumatic (piston) damper system which requires an external supplyof compre

Page 50

504. Steam Damper System OperationThe ADS-200 steam damper in the Heating Mode as shown in Diagram 1, allows the coil to stay constantlycharged elimin

Page 51 - H. STEAM INFORMATION

51I. STEAM DAMPER ACTUATOR SYSTEMThe system consists of a hinged damper plate, pneumatic piston, and a 24 volt solenoid valve with a needle valveto c

Page 52

52K. PREOPERATIONAL TESTSALL dryers are thoroughly tested and inspected before leaving the factory. However, a preoperational testshould be preforme

Page 53 - Normal 80 PSI 5.51 bars

53NOTE: Dryer can be stopped at any time by opening the main door or by pressing the “CLEAR/STOP” key. To restart the dryer, press the “ENTER/START”

Page 54

542) Make a complete operational check of ALL safety-related circuits (i.e., lint drawer switch and sailswitches on Gas Models).3) A reversing tumbler

Page 55

5510. Check bolts, nuts, screws, terminals, and fittings for security.11. Check to insure air supply (80 PSI [5.51 bars]) is connected to the dryer.12

Page 56 - K. PREOPERATIONAL TESTS

SECTION VIICOMPONENT SYSTEM DESCRIPTIONS... 62A. TUMBLER DRIVE SYSTEM

Page 57

56SECTION IVSERVICE/PARTS INFORMATIONA. SERVICE1. Service must be performed by a qualified trained technician, service agency, or gas supplier. If s

Page 58

57SECTION VWARRANTY INFORMATIONA. RETURNING WARRANTY CARD(S)1. Before any dryer leaves the ADC factory test area, a warranty card is placed on the ba

Page 59 - M. SHUT DOWN INSTRUCTIONS

582. Each part must be tagged with the following information:a. Model number and serial number of the dryer from which the part was removed.b. Nature

Page 60 - SECTION IV

59SECTION VIROUTINE MAINTENANCEA. CLEANINGA program and/or schedule should be established for periodic inspection, cleaning, and removal of lint from

Page 61 - SECTION V

60MONTHLYEmpty the compressed air filter bowl.EVERY THREE MONTHSRe-grease the two (2) 1-3/8-inch (3.5 cm) bearings that support the impellor/fan shaft

Page 62

61B. ADJUSTMENTS7 DAYS AFTER INSTALLATION and EVERY 6 MONTHS THEREAFTERInspect bolts, nuts, screws (bearing set screws), non-permanent gas connection

Page 63 - SECTION VI

62SECTION VIICOMPONENT SYSTEM DESCRIPTIONSA. TUMBLER DRIVE SYSTEMThe tumbler (basket) is supported and driven by four (4) 11-inch (27.94 cm) diameter

Page 64

63B. TUMBLERThe tumbler (basket) is made of 14-gauge stainless steel perforated panels, four (4) stainless steel ribs, and two(2) outer tumbler rings

Page 65 - C. LUBRICATION

644. Burner Box Hi-Limit Safety Thermostats (for Gas Dryers ONLY)These disk temperature switches have a setting of 330º F (166º C). They are located

Page 66 - SECTION VII

65E. STEAM DAMPER ACTUATOR SYSTEMThe system consists of a hinged damper plate, pneumatic piston, and a 24 volt solenoid valve with a needle valveto c

Page 67 - D. SAFETY DEVICES

3SECTION IIMPORTANT INFORMATIONA. RECEIVING and HANDLINGThe dryer is shipped in a protective stretch wrap cover with protective cardboard corners as

Page 68

ADC 113109 1- 02/09/00-25 2- 05/26/00-20 3* 01/02/01-10

Page 69

4B. SAFETY PRECAUTIONSWARNING: For your safety, the information in this manual must be followed to minimize therisk of fire or explosion or to preve

Page 70

5WARNING: DO NOT use heat for drying articles that contain plastic, foam, sponge rubber, orsimilarly textured rubber materials. Drying in a heated tu

Commentaires sur ces manuels

Pas de commentaire