American Dryer Corp. AD-78 Manuel d'installation

Naviguer en ligne ou télécharger Manuel d'installation pour Sèche-linge électrique American Dryer Corp. AD-78. American Dryer Corp. AD-78 Installation manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 48
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
AD-78 III
(Gas HSI - Phase 7/FSS)
Installation Manual
For replacement parts, contact the reseller from which the dryer
was purchased or
American Dryer Corporation
88 Currant Road
Fall River MA 02720-4781
Telephone: (508) 678-9000 / Fax: (508) 678-9447
www.amdry.com
WARNING: For your safety the information in
this manual must be followed to minimize the
risk of fire or explosion or to prevent property
damage, personal injury or death.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Clear the room, building or area of all
occupants.
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
If you cannot reach your gas supplier, call
the fire department.
Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
AVERTISSEMENT: Assurez-vous de bien
suivre les instructions données dans cette notice
pour réduire au minimum le risque d’incendie
ou d’explosion ou pour éviter tout dommage
matériel, toute blessure ou la mort.
Ne pas entreposer ni utiliser d’essence ni
d’autres vapeurs ou liquides inflammables à
proximité de cet appareil ou de tout autre
appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR
DE GAZ:
Ne pas tenter d’allumer d’appareils.
Ne touchez à aucun interrupteur. Ne pas
vous servir des téléphones se trouvant dans
le bâtiment.
Évacuez la pièce, le bâtiment ou la zone.
Appelez immédiatement votre fournisseur
de gaz depuis un voisin. Suivez les
instructions du fournisseur.
Si vous ne pouvez rejoindre le fournisseur
de gaz, appelez le service des incendies.
L’installation et l’entretien doivent être assurés par
un installateur ou un service d’entretien qualifié
ou par le fournisseur de gaz.
082401JEV/tcosta ADC Part No. 113340
Vue de la page 0
1 2 3 4 5 6 ... 47 48

Résumé du contenu

Page 1 - Installation Manual

AD-78 III(Gas HSI - Phase 7/FSS)Installation ManualFor replacement parts, contact the reseller from which the dryerwas purchased orAmerican Dryer Corp

Page 2 - Important

6SECTION IISPECIFICATIONS/COMPONENT IDENTIFICATIONA. SPECIFICATIONSShaded areas are stated in metric equivalents* For non-reversing models only.** A

Page 3 - FOR YOUR SAFETY

7SpecificationsADG-78 III (Gas)NOTE: ADC reserves the right to make changes in specifications at any time without notice orobligation.

Page 4

8B. COMPONENT IDENTIFICATION1. Dryer Front ViewIllus. No. Description1 Controls2 Control (top access) Door Assembly3 Main Door Assembly4 Lint Compart

Page 5 - Table of Contents

92.Dryer Rear ViewIllus. No. Description1 Heating Unit2 Top Console3* Electric Service Relay Box4 Basket (tumbler) Bearing Mount Assembly5 Idler Bear

Page 6

10SECTION IIIINSTALLATION PROCEDURESInstallation should be performed by competent technicians in accordance with local and state codes. In theabsence

Page 7 - SECTION I

11CAUTION: This dryer produces combustible lint and must be exhausted to the outdoors. Every 6months, inspect the exhaust ducting and remove any lint

Page 8 - B. SAFETY PRECAUTIONS

12c. Remove the four (4) self-tapping screws on the burner box that secure it to the top of the dryer (referto the illustration below).d. Remove the t

Page 9

13C. DRYER ENCLOSURE REQUIREMENTSBulkheads and partitions should be made of noncombustible materials and must be located a minimum of12-inches (30

Page 10 - SECTION II

14D. FRESH AIR SUPPLY REQUIREMENTSWhen the dryer is operating, it draws in room air, heats it, passes this air through the basket (tumbler), andexhau

Page 11 - ADG-78 III (Gas)

15E. EXHAUST REQUIREMENTS1. General Exhaust Ductwork InformationExhaust ductwork should be designed and installed by a qualified professional. Impro

Page 12 - B. COMPONENT IDENTIFICATION

AD-78 IIIRetain This Manual In A Safe Place For Future ReferenceAmerican Dryer Corporation products embody advanced concepts in engineering, design, a

Page 13

16IMPORTANT: Exhaust back pressure measured by a manometer in the exhaust duct must be no lessthan 0 and must not exceed 0.3 inches (0.74 mb) of water

Page 14 - SECTION III

17IMPORTANT: Minimum duct size for a dryer that is vented vertically is 12-inches (30.48 cm) for around duct or an equivalent of 80 square inches (516

Page 15 - B. UNPACKING/SETTING UP

18F. ELECTRICAL INFORMATION1. Electrical RequirementsIt is your responsibility to have ALL electrical connections made by a properly licensed and com

Page 16

192.Electrical Service SpecificationsIMPORTANT: The dryer must be connected to the electric supply shown on the data label that isaffixed to the left

Page 17

203. GroundingA ground (earth) connection must be provided and installed in accordance with state and local codes. Inthe absence of these codes, grou

Page 18

21b. 3-Phase (3ø) Wiring Connections (Hookup) - For Non-Reversing Models OnlyThe electrical connections on ALL 3-phase (3ø) gas model dryers are made

Page 19 - E. EXHAUST REQUIREMENTS

221) Gas ModelsThe only electrical input connections to the dryer are the 3-phase (3ø) power leads (L1, L2, L3, andsometimes neutral) and ground. Sin

Page 20

23c. 3-Phase (3ø) Wiring Connections (Hookup) - For Reversing Models OnlyThe electrical connections on ALL 3-phase (3ø) gas model dryers are made into

Page 21

24G. GAS INFORMATIONIt is your responsibility to have ALL plumbing connections made by a qualified professional to assure that the gasplumbing instal

Page 22 - F. ELECTRICAL INFORMATION

252. Technical Gas Dataa. Gas Specificationsb. Gas ConnectionsInlet connection -------- 3/4 N.P.T.Inlet supply size -------- 3/4 N.P.T. (minimum)Btu

Page 23

IMPORTANTYOU MUST DISCONNECT AND LOCKOUT THE ELECTRIC SUPPLY AND THE GASSUPPLY BEFORE ANY COVERS OR GUARDS ARE REMOVED FROM THEMACHINE TO ALLOW ACCES

Page 24

263.Piping/ConnectionsALL components/materials must conform to National Fuel Gas Code Specifications ANSI Z223.1-LATESTEDITION, or in Canada, CAN/CG

Page 25 - CONNECTIONS LEADS

27Consistent gas pressure is essential at ALL gas connections. It is recommended that a 3/4-inch (19.050mm) pipe gas loop be installed in the supply

Page 26

28H. PREPARATION FOR OPERATION/START-UPThe following items should be checked before attempting to operate the dryer:1. Read ALL CAUTION, WARNING

Page 27

29I. PREOPERATIONAL TESTSALL dryers are thoroughly tested and inspected before leaving the factory. However, a preoperational testshould be performe

Page 28 - G. GAS INFORMATION

30NOTE: To check for proper sail switch operation (for gas models only), open the main door and whileholding main door switch plunger in, start dryer.

Page 29 - TYPE OF GAS

31J. PREOPERATIONAL INSTRUCTIONS1. To start the dryer:a. Microprocessor Controller (Computer) Dryers...1) The light emitting diode (L.E.D.) display w

Page 30

32SECTION IVSERVICE/PARTS INFORMATIONA. SERVICE1. Service must be performed by a qualified trained technician, service agency, or gas supplier. If s

Page 31

33SECTION VWARRANTY INFORMATIONA. RETURNING WARRANTY CARDS1. Before any dryer leaves the ADC factory test area, a warranty card is placed on the back

Page 32

342. Each part must be tagged with the following information:a. Model number and serial number of the dryer from which part was removed.b. Nature of f

Page 33 - I. PREOPERATIONAL TESTS

35SECTION VIROUTINE MAINTENANCEA. CLEANINGA program and/or schedule should be established for periodic inspection, cleaning, and removal of lint from

Page 34

WARNINGThe dryer must never be operated with any of the back guards, outer tops, or servicepanels removed. PERSONAL INJURY OR FIRE COULD RESULT.IMPOR

Page 35 - K. SHUT DOWN INSTRUCTIONS

3690 DAYS1. Remove lint from around basket (tumbler), drive motors, and surrounding areas.2. Remove lint from gas valve burner area with a dusting br

Page 36 - SECTION IV

37SECTION VIIREVERSING TIMER SPIN/DWELL ADJUSTMENTSTimer models have an electronic reversing timer in the electrical service box, which is located in

Page 37 - SECTION V

38SECTION VIIIDATA LABEL INFORMATIONA. DATA LABELWhen contacting American Dryer Corporation, certain information is required to insure proper service

Page 38

39THE DATA LABEL1. MODEL NUMBERThe model number is an ADC number, which describes the size of the dryer and thetype of heat (gas, electric, or steam)

Page 39 - SECTION VI

40SECTION IXPROCEDURE FOR FUNCTIONAL CHECKOF REPLACEMENT COMPONENTS1. Microprocessor Controller (Computer) Boarda. Upon completing installation of the

Page 40 - C. LUBRICATION

412.For Models With Hot Surface Ignition (HSI) Module (CE Version)a. Upon completing installation of the replacement HSI module, reestablish power to

Page 41 - SECTION VII

42SECTION XBURNER AND BASKET (TUMBLER)/LINT CHAMBERMANUAL RESET HI-LIMIT INSTRUCTIONSIMPORTANTMANUAL RESET HI-LIMIT INSTRUCTIONSFOR PHASE 7 MODELST

Page 42 - SECTION VIII

43IMPORTANTMANUAL RESET HI-LIMIT INSTRUCTIONSDUAL TIMER MODELS ONLYThis dryer was manufactured with a burner manual reset hi-limit thermostat, a

Page 43

ADC 113340 1 - 08/28/01-15 2-09/27/01-25 3*03/25/02-25

Page 44 - SECTION IX

Table of ContentsSECTION IIMPORTANT INFORMATION...3A. Receiving and Handling ..

Page 45

SECTION VIIREVERSING TIMER SPIN/DWELL ADJUSTMENTS ...37SECTION VIIIDATA LABEL INFORMATION...

Page 46 - SECTION X

3SECTION IIMPORTANT INFORMATIONA. RECEIVING AND HANDLINGThe dryer is shipped in a protective stretch wrap cover with protective cardboard corners and

Page 47

4B. SAFETY PRECAUTIONSWARNING: For your safety, the information in this manual must be followed to minimize the risk offire or explosion or to preven

Page 48

57. A program should be established for the inspection and cleaning of lint in the burner area, exhaust ductwork,and area around the back of the dryer